Water Valve Leak Mitigation
| Bidders ID: | NBD00159908425270195 |
|---|---|
| Due Date: | Sep 3, 2026 |
| Posted Date: | Jul 9, 2026 |
| Level of Government: | Federal |
| State: | Federal |
| Agency: | ENERGY, DEPARTMENT OF |
| Category: |
|
| Solicitation Number: | FMP-NNL-0047 |
| Source: | Members Only |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Jul 09, 2026 09:05 am EDT
- Original Response Date: Sep 03, 2026 05:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Sep 04, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: AG12 - ENERGY R&D SERVICES; ENERGY SUPPLY; APPLIED RESEARCH
-
NAICS Code:
- 54171 - Research and Development in the Physical, Engineering, and Life Sciences
-
Place of Performance:
USA
THIS IS A REQUEST FOR INFORMATION ONLY. THIS IS NOT A SOLICITATION.
This notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion (FMP), is utilizing this request for information for market research to determine what organizations have the capability to fulfill this requirement. NNL will not be responsible for any costs incurred by interested parties in responding to this request for information.
Responses shall not exceed five (5) pages in length.
Scope:
When performing maintenance on a pure water fluid system, valves are commonly used for work area isolation. Valves that have been in-service can leak past their seats. In this case, the worker may still be protected from hazardous energy on the other side of the valve but work such as welding might not be possible if water is being continually introduced to the work area. In this case, more valves can be used if available in the system design, but if not, freeze seals are commonly used to eliminate leakage. Freeze seals can consume significant work and resources to set, so alternate means to mitigate water leakage past valves is desired.
A method to mitigate valve leak-by for the hours or days a system is open for maintenance or the time to perform a weld is desired which will not affect pure water chemistry or stainless-steel corrosion or cracking performance. The method must not introduce devices or materials that require removal from the system after repair is completed. Solutions must either be external to the system, completely dissolve into known and consistent constituents at room temperature, or otherwise non-intrusive.