Notice of Intent (NOI) to Sole Source AND Request for Information (RFI)

Bidders ID: NBD00159607927483691
Due Date: Sep 30, 2026
Posted Date: Sep 14, 2026
Level of Government: Federal
State: Minnesota
Agency: DEPT OF DEFENSE
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation Number: PANGLR-26-P-0000030113
Source: Members Only
Follow
Notice of Intent (NOI) to Sole Source AND Request for Information (RFI)
Active
Contract Opportunity
Notice ID
PANGLR-26-P-0000030113
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
US ARMY CORPS OF ENGINEERS
Sub Command
ENGINEER DIVISION GREAT LAKES AND OHIO
Sub Command 2
ENDIST DETROIT
Office
W072 ENDIST DETROIT
General Information
  • Contract Opportunity Type: Special Notice (Original)
  • Original Published Date: Sep 14, 2026 01:46 pm EDT
  • Original Response Date: Sep 30, 2026 02:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Oct 01, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: Z2PZ - REPAIR OR ALTERATION OF OTHER NON-BUILDING FACILITIES
  • NAICS Code:
    • 237990 - Other Heavy and Civil Engineering Construction
  • Place of Performance:
    Duluth , MN 55802
    USA
Description

Notice of Intent (NOI) to Sole Source AND Request for Information (RFI)



Notice of Intent (NOI) for Brand Name Appleton Powertite® Series Receptacles as part of the Duluth Vessel Yard Phase III Repairs construction contract. The Duluth Vessel Yard Phase III Repairs project is located in Duluth, Minnesota.



Description:



The U.S. Army Corps of Engineers (USACE), Detroit District, anticipates publicizing a solicitation for a construction contract for the Duluth Vessel Yard Phase III Repairs located in Duluth, MN. As part of this procurement, USACE Detroit District intends to specify a portion of the acquisition for the brand-name requirement on a sole-source basis under the authority of Revolutionary FAR Overhaul (RFO) 6.103-1(b) One Responsible Source for the Appleton Powertite® series connectors to the Manufacturer, Appleton Grp LLC (Emerson).



The required brand-name elements are the shore-side electrical pin-and-sleeve receptacles. These receptacles are integral components of the vessel shorepower distribution system, providing high-amperage electrical connections for the USACE Floating Plant. They are designed to safely and seamlessly mate with existing vessel power umbilical cords (plugs) without requiring electrical modification, physical plug replacement, or physical retooling of the vessels' systems. Appleton Grp LLC is the sole manufacturer of the proprietary Powertite® series connection systems. The connectors are to be purchased and installed by the prime Contractor or their electrical subcontractors.



The specific brand-name receptacle parts required to be purchased are:




  • Appleton Powertite® Series 60 Amp, 600VAC/250VDC, Female Receptacle (Pin-and-Sleeve)

  • Appleton Powertite® Series 200 Amp, 600VAC/250VDC, Female Receptacle (Pin-and-Sleeve)

  • Matching Appleton Powertite® Weatherproof Spring-Loaded Lift Covers/Caps



A minimum of a one (1) year manufacturer warranty will be required on the purchased connector parts.



Disclaimer



This NOI is being issued to provide notification of the Government’s intent to sole source the brand-name portion of the requirement and obtain industry feedback through the RFI process. This is not a request for a competitive bid. This is not a solicitation, and the information contained herein is subject to change or be eliminated from the requirement. Only firms capable of providing a compatible equivalent product are requested to respond by email. Oral communications are not acceptable in response to this notice.



Responses



Interested parties able to source and procure a directly compatible equivalent product may identify their interest and capability in writing to the identified points of contact below, no later than September 30, 2026, at 2:00pm (Eastern).



Please include the following in your response:



1. Name of Firm



2. UEI or Cage Code



3. Point of Contract, Phone Number, and Email Address



4. Supporting technical documentation to illustrate the directly compatible equivalent product(s) that safely and seamlessly mate with the existing Appleton Powertite® male plugs.



Submit any information for consideration by the Government via email to the Contract Specialist and Contracting Officer listed below using the Subject Line: NOI for Brand Name Appleton Connectors (Appleton Grp LLC).



Reminder



Responses shall be evaluated solely for the purpose of determining whether or not to conduct this portion of the procurement on a competitive basis. A determination by the Government, based upon responses received from this notice, is solely at the discretion of the Government.


Attachments/Links
Contact Information
Contracting Office Address
  • CONTRACTING OFFICE KO 477 MICHIGAN AVE
  • DETROIT , MI 48226-5000
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Sep 14, 2026 01:46 pm EDTSpecial Notice (Original)

Related Document

Sep 14, 2026[Presolicitation (Original)] Duluth Vessel Yard Phase III Repairs
Disclaimer: The details regarding bids, requests for proposals (RFPs), and requests for qualifications (RFQs) on this site are provided for convenience and do not represent official public notice. To respond to or inquire about bids, RFPs, or RFQs, please contact the appropriate government department.

TRY FOR FREE

Not a GovernmentBidders Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >