Chain Link Enclosure Installation; San Diego CA
Bidders ID: | NBD00159187906316043 |
---|---|
Due Date: | Sep 10, 2024 |
Posted Date: | Sep 4, 2024 |
Level of Government: | Federal |
State: | California |
Agency: | HOMELAND SECURITY, DEPARTMENT OF |
Category: |
|
Solicitation Number: | RFQ70CMSD24Q00000036 |
Source: | Members Only |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- All Dates/Times are: (UTC-05:00) CENTRAL STANDARD TIME, CHICAGO, USA
- Original Published Date: Sep 04, 2024 12:06 pm CDT
- Original Date Offers Due: Sep 10, 2024 12:00 pm CDT
- Inactive Policy: Manual
- Original Inactive Date: Sep 11, 2024
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 4010 - CHAIN AND WIRE ROPE
-
NAICS Code:
- 238990 - All Other Specialty Trade Contractors
-
Place of Performance:
San Diego , CA 92154USA
We are seeking a vendor to provide a firm fixed price quote to provide and install a chain link enclosure within a warehouse. The specifications for the project are as follows: 1. Enclosure Dimensions: Install a chain link enclosure measuring 47 ft (length) x 14 ft (width) x 10 ft (height), including a chain link roof. 2. Roof Structure: All roof structural elements must be welded in place. Fabricate and install six (6) trusses, each measuring 1 5/8 in. x 12 in. x 14 ft, to support the roof. 3. Bracing: Install five (5) rows of 1 5/8 in. bracing on top of the enclosure to support the roof's weight. 4. Gate: Fabricate and install one (1) slide gate, measuring 6 ft x 10 ft. 5. Anchoring: All posts must be anchored using 12 in. x 3 in. Red Heads. 6. Material Specifications: All materials used must be heavy Schedule 50 Commercial Grade, in compliance with government specifications. Please refer to the attached photo of the warehouse interior for context. We look forward to receiving your quotation and detailed proposal for this installation project.
- 500 12TH STREET SW
- WASHINGTON , DC 20024
- USA
- charles maves
- charles.maves@ice.dhs.gov
- Sep 04, 2024 12:06 pm CDTCombined Synopsis/Solicitation (Original)
Related Document
Sep 10, 2024 | [Combined Synopsis/Solicitation (Updated)] Chain Link Enclosure Installation; San Diego CA |
TRY FOR FREE
Not a GovernmentBidders Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.